Diabetes Care

BeneCheck Supreme Multi-Monitoring System

BX-M000, BX-M00D
Features
3 in 1 Multi-Function: Blood Glucose, Uric Acid, Total Cholesterol
HCT calibration (broader hematocrit range)
Bluetooth (BX-M00D, optional)
Auto-Ejection
ISO 13485
CE certificate
Made in Taiwan

Description

BeneCheck Supreme Multi-Monitoring System offers a versatile three-in-one function. With different strips, it effortlessly measures blood glucose, total cholesterol, and uric acid. As a certified medical device with CE approval, it features Hematocrit calibration technology, ensuring accurate readings by eliminating interference from blood cells across a wide hematocrit range.

Add Inquiry (0)

Advantages of the BeneCheck Multi-Function Monitoring System

  • The BeneCheck Multi-Function Monitoring System is a 3-in-1 health monitoring device that quickly checks glucose, uric acid, and total cholesterol. It is suitable for families managing diabetes, gout, and high cholesterol.
  • Exclusive HCT automatic correction technology significantly reduces red blood cell interference, providing more accurate measurement results.
  • Glucose testing takes only 5 seconds; simple operation with auto-coding.
  • Certified by the Taiwan FDA and EU regulations; reliable quality.
  • Portable design allows you to track health data anytime, preventing the risk of chronic diseases.

 

Common Questions about the Multi-Function Monitoring System

 
Why are the measurement results different from hospital blood tests?

Home monitoring devices use fingertip whole blood, while hospitals test venous plasma. Due to different sampling sites and methods, slight differences in values are normal (home values are usually slightly lower). Additionally, glucose, uric acid, and total cholesterol fluctuate instantly with time, diet, stress, and exercise.

The BeneCheck system complies with international ISO 15197 standards: When glucose is < 100 mg/dL, the error range is within ±15 mg/dL; when ≥ 100 mg/dL, the error is within ±15%.

It is recommended to compare results **while fasting**. If you still have concerns, please bring the device to a medical institution for verification.

What should I do if an error code appears or blood volume is insufficient?

Common causes include insufficient blood volume, damp strips, or incorrect insertion. Solutions:

  • Ensure fingers are clean and dry (alcohol must evaporate completely).
  • Uric Acid/Total Cholesterol tests require more blood (1.0 μL/0.8 μL). Wash hands with warm water and massage fingertips to promote blood circulation, or adjust the lancing depth.
  • Use test strips within 3 months of opening; avoid storing in damp environments.
  • If errors persist, check the battery or contact customer service.
How to store test strips and maintain the device?

Test strips are key to accuracy. Please note:

  • Use strips within 3 months of opening. Do not refrigerate (store at room temperature).
  • Close the cap tightly immediately after use to avoid humidity or direct sunlight.
  • Device maintenance: wipe with a dry cloth, avoid washing with water; replace batteries promptly when low.

 

Test Strip Specifications

 Item  GLU
 Blood Glucose Strip
 CHOL
 Total Cholesterol Strip
 UA
 Uric Acid Strip
 Model Number  BK-SG1  BK-SC2  BK-SU1
 Principle  Electrochemistry  Electrochemistry  Electrochemistry
 Test Sample  Fingertip, Venous Blood  Fingertip  Fingertip
 Hematocrit range  0% – 70%  30% – 60%  20% – 70%
 Measuring Time  5 seconds  26 seconds  15 seconds
 Measuring Range  20 – 600 mg/dL
 (1.1 – 33.3 mmol/L)
 100 – 400 mg/dL
 (2.59 – 10.35 mmol/L)
 3 – 20 mg/dL
 (0.18 – 1.19 mmol/L)
 Sample Volume  0.7 μL  0.8 μL  1.0 μL
 Memory  360 Test Results  50 Test Results  50 Test Results
Others Glucose dehydrogenase, Auto-coding - -

 

Meter Specifications

Dimensions (L × W × H): Approx. 95 × 60 × 20 mm
Weight: Approx. 71g (including batteries)
Power / Battery: 1.5V AAA Battery × 2

 